Albemarle County Criteria for Prioritizing Secondary Road Improvements with Subsetting Data

 

 

Major Reconstruction

 

Growth Management Policy/ In Adopted Plan 

  1. Growth
  2. RA, non watershed
  3. RA, watershed

 

AADT (Average Annual Daily Trip)

  1. 10,001 or greater
  2. 5,001-10,000
  3. 3,501-5,000
  4. 1,501-3,500
  5. 100-1,500
  6. Less than 100

 

School / Fire Rescue Request

 

Functional Classification

  1. Freeway
  2. Arterial
  3. Collector
  4. Local

 

Right of Way Availability

  1. Proposed Improvement can be done w/in VDOT or County ROW
  2. Proposed Improvement cannot be done w/in VDOT or County ROW

 

 

Unpaved Roads (Traditional)

 

 

AADT

  1. 10,001 or greater
  2. 5,001-10,000
  3. 3,501-5,000
  4. 1,501-3,500
  5. 100-1,500
  6. Less than 100

 

 

 

Growth Management Policy/In Adopted Plan

  1. Growth
  2. RA, non watershed
  3. RA, watershed

 

School / Fire Rescue Request

 

Functional Class

  1. Freeway
  2. Arterial
  3. Collector
  4. Local

 

Number of homes on road segment

  1. 51 or greater
  2. 36-50
  3. 21-35
  4. 10-21
  5. Less than 10

 

Road width

  1. Less than 16 feet
  2. 17-22 feet
  3. 22 feet or more

 

Right of Way Availability

  1. Proposed Improvement can be done w/in VDOT or County ROW
  2. Proposed Improvement cannot be done w/in VDOT or County ROW

 

Shoulder Width

  1. 0-2 feet
  2. 2-6 feet
  3. 6 or more feet
  4. Curb and gutter

 

 

Unpaved Road (Rural Rustic Roads)

 

AADT

  1. 10,001 or greater
  2. 5,001-10,000
  3. 3,501-5,000
  4. 1,501-3,500
  5. 100-1,500
  6. Less than 100

 

 

Growth Management Policy/In Adopted Plan

  1. Growth
  2. RA, non watershed
  3. RA, watershed

 

School / Fire Rescue Request

 

Number of homes on road segment

  1. 51 or greater
  2. 36-50
  3. 21-35
  4. 10-21
  5. Less than 10

 

Road Width staff will confer with VDOT for vertical and horizontal alignment information

 

Shoulder Width

  1. 0-2 feet
  2. 2-6 feet
  3. 6 or more feet
  4. Curb and gutter

 

 

Bridge Replacement / Improvement

 

VDOT Bridge Sufficiency Rating

  1. 0-10
  2. 10-20
  3. 20.1 or greater

 

AADT

  1. 10,001 or greater
  2. 5,001-10,000
  3. 3,501-5,000
  4. 1,501-3,500
  5. 100-1,500
  6. Less than 100

 

School / Fire Rescue Request

 

Functional Class

  1. Freeway
  2. Arterial
  3. Collector
  4. Local

Growth Management Policy/In Adopted Plan

  1. Growth
  2. RA, non watershed
  3. RA, watershed

 

 

Spot Improvements

 

AADT

  1. 10,001 or greater
  2. 5,001-10,000
  3. 3,501-5,000
  4. 1,501-3,500
  5. 100-1,500
  6. Less than 100

 

Growth Management Policy/In Adopted Plan

1.      Growth

2.      RA, non watershed

3.      RA, watershed

 

School / Fire Rescue Request

 

Functional Class

  1. Freeway
  2. Arterial
  3. Collector
  4. Local

 

Pavement Width

  1. Less than 16 feet
  2. 17-22 feet
  3. 22 feet or more

 

Surface Type

  1. Unpaved (gravel, all weather)
  2. Prime and double seal
  3. Plant Mix

 

 

 

At-Grade Railroad Crossing

 

 

Existing Protection Services

  1. No Lights
  2. Light 

AADT

  1. Less than 100
  2. 100-200
  3. 201-500
  4. 500-1,000
  5. 1,000 or greater

 

Sight Distance at Crossing

 

School / Fire Rescue Request

 

Growth Management Policy/In Adopted Plan

  1. Growth
  2. RA, non watershed
  3. RA, watershed

 

Number of Trains per day

  1. 10 or more
  2. 6-10
  3. 3-5
  4. 0-2

Go to Attachment B
Return to exec summary